Product Overview
The Genolution Nextractor® NX-48N is a fully automated, magnetic-bead nucleic acid extraction system designed to process from one to 48 samples per run. Pre-filled reagent formats support 1-, 8- and 24-sample workflows without changing the instrument’s hardware or software format, helping laboratories match each run to the number of samples received.
Depending on the sample type and protocol, extraction is completed in approximately 15–30 minutes. The system supports 200–400 µL sample input and 50–150 µL elution volumes, with pre-programmed and customizable protocols operated through a 7-inch LCD touchscreen.
Important: Extraction performance, specimen compatibility and downstream suitability depend on the selected reagent kit and validated protocol. Confirm the intended use and regulatory status of the complete instrument, reagent and application workflow for your laboratory and jurisdiction.
Up to 48 Samples
Run one to 48 samples with pre-filled reagent formats sized for different batch requirements.
15–30 Minute Extraction
Turnaround time varies with the specimen type, extraction kit and selected protocol.
Flexible Batch Sizes
Prefilled 1-, 8- and 24-sample formats can be used without reconfiguring the platform.
Key Features
- Automated magnetic-bead extraction of DNA and RNA
- Processes one to 48 samples in a single run
- Approximately 15–30 minutes per run, depending on sample type and protocol
- Pre-filled reagent formats for 1, 8 or 24 samples
- 200–400 µL sample input volume
- 50–150 µL elution volume
- Pre-programmed and customizable extraction protocols
- 7-inch LCD touchscreen interface
- Automatic axis adjustment and auto-calibration
- UV sterilization function and door sensor
- Heating range from room temperature to 120°C
Product Specifications
| Jant Catalog Number | GNNX48N |
|---|---|
| Model | Nextractor NX-48N |
| Extraction Method | Automated magnetic-bead nucleic acid extraction |
| Maximum Throughput | 48 samples per run |
| Typical Run Time | 15–30 minutes, depending on sample type and protocol |
| Reagent Format | Pre-filled formats for 1, 8 or 24 samples |
| Sample Input Volume | 200–400 µL |
| Elution Volume | 50–150 µL |
| User Interface | 7-inch LCD touchscreen |
| Protocols | Pre-programmed and customizable protocols |
| Heating Range | Room temperature to 120°C |
| Safety / Decontamination | UV sterilization function and door sensor |
| Calibration | Automatic axis adjustment and auto-calibration |
| Dimensions | 385 mm W × 390 mm D × 400 mm H |
| Weight | 25 kg |
| Power | AC 100–240 V, 3.0–1.5 A, 50/60 Hz |
Automated Extraction Workflow
Select the Workflow
Choose the validated extraction kit and protocol for the specimen type and downstream application.
Load Samples and Reagents
Prepare the appropriate pre-filled reagent format, add samples and load the instrument according to the kit instructions.
Run and Collect
Start the selected protocol and collect the purified nucleic acid for the validated downstream workflow.
This is a general workflow summary. Follow the current instrument manual, extraction-kit instructions and laboratory procedures.
Compare Nextractor Systems
Select the platform that best matches your typical batch size and laboratory footprint.
| Model | Samples per Run | Reagent Format | Best Fit |
|---|---|---|---|
| NX-48N | 1–48 | 1-, 8- and 24-sample pre-filled formats | Flexible medium- to high-throughput workflows |
| NX-48S | Up to 48 | 1-, 8- and 24-sample pre-filled formats | Established 48-sample extraction workflows |
| NX-Jr | 1–8 | Individual pre-filled cartridges | Lower-volume labs and compact spaces |
Build the Complete Molecular Workflow
Extraction Reagents
Review DNA and RNA extraction kits and confirm compatibility with the selected Nextractor model.
Real-Time PCR
Connect nucleic acid extraction with Jant’s standard, custom and pharmacogenomic RT-PCR offerings.
Automated Extraction Systems
Compare additional extraction platforms for different throughput and workflow requirements.
Documentation and Resources
Nextractor NX-48N BrochureFrequently Asked Questions
The NX-48N can process from one to 48 samples in a run. Available pre-filled reagent formats support different batch sizes without changing the instrument format.
Typical turnaround is approximately 15–30 minutes. Actual time depends on the sample type, extraction kit and selected protocol.
The published instrument specifications list 200–400 µL sample input and 50–150 µL elution volume. Kit-specific requirements may vary and should be confirmed in the applicable instructions.
Yes. The 7-inch touchscreen provides access to pre-programmed protocols and supports customized protocols for qualified workflows.
Compatibility depends on the sample type and application. Review the Genolution extraction-kit page and confirm the exact kit, format and protocol with Jant before ordering.
The NX-48N is designed to produce nucleic acid for downstream molecular workflows. The complete extraction and RT-PCR process must be validated using the selected specimen, reagent kit, assay and instrument configuration.
Ordering Information
To place an order or request information, call Jant Pharmacal at 800.676.5565
| Catalog Number | Description | Unit of Measurement |
|---|---|---|
| GNNX48N | Genolution Nextractor NX-48N Automated Nucleic Acid Extraction System | 1 system |
Extraction reagents, consumables, installation and service items are quoted separately unless specifically included.