Product Overview
Genolution DNA/RNA extraction kits provide prefilled reagents for automated magnetic-bead nucleic acid isolation on compatible Nextractor systems. The available kit families support a range of specimen types, including blood, cultured cells, tissue, FFPE material, stool, urine, swabs, respiratory specimens, serum and plasma.
Select the extraction kit according to the specimen, required nucleic acid type, Nextractor model and downstream method. Prefilled formats help simplify setup and reduce manual reagent handling, while instrument protocols automate the binding, washing and elution steps.
Important: Not every kit or reagent format is compatible with every Nextractor model. Kit availability, pack size, specimen compatibility, intended use and regulatory status vary. Confirm the exact kit, instrument protocol and application requirements with Jant before ordering.
Prefilled Reagents
Model-specific plates or cartridges reduce reagent preparation and support a streamlined automated workflow.
Broad Sample Coverage
Choose from kit families developed for blood, cells, tissue, FFPE, stool, urine, swabs and other supported specimens.
Downstream Flexibility
Purified nucleic acid can support validated molecular workflows such as PCR and real-time PCR.
Choose an Extraction Kit by Sample Type
The table below organizes the extraction-kit families currently represented on this page. Confirm the current kit name, format and instrument compatibility before ordering.
| Kit Family | Representative Sample Types | Extraction Focus |
|---|---|---|
| Bacterial DNA Kit | Raw sputum, pretreated sputum, bronchial secretions, cerebrospinal fluid, urine and cell culture | Bacterial DNA isolation for applicable molecular workflows |
| Cell DNA/RNA Kit | Cultured cells | DNA or RNA isolation from cellular material |
| FFPE DNA Kit | Formalin-fixed, paraffin-embedded material and tissue | DNA isolation from fixed tissue samples |
| Food DNA Kit | Food and feed | DNA isolation for applicable food-analysis workflows |
| Genomic DNA Kit | Whole blood, buffy coat, buccal swab and saliva | Genomic DNA extraction |
| Stool DNA/RNA Kit | Stool, fecal material and rectal swab | Nucleic acid isolation from stool-related specimens |
| Tissue DNA Kit | Tissue and meat | DNA isolation from tissue samples |
| Urine/Swab DNA Kit | Urine, cervical swab, genital or vaginal swab, expressed prostatic secretion and semen | DNA isolation for applicable molecular workflows |
| Viral DNA/RNA/NA Kit | Serum, plasma, nasal swab and other supported specimens | Viral nucleic acid extraction for validated testing or research workflows |
Sample types are representative and are not a substitute for the current kit instructions. Pretreatment, input-volume and storage requirements may vary.
Nextractor Instrument Compatibility
Reagent presentation varies by instrument. Use only the kit format and protocol specified for the selected model.
| Nextractor Model | Published Reagent Presentation | Before Ordering |
|---|---|---|
| NX-48N | Prefilled formats supporting 1-, 8- and 24-sample workflows | Confirm the kit family, pack configuration and installed protocol |
| NX-48S | Prefilled 4-, 32- or 96-well formats for single-, 8- or 24-sample workflows | Confirm the kit family, plate format, package size and protocol |
| NX-Jr | Individual prefilled cartridges | Confirm that the selected kit and protocol are available for NX-Jr |
Compatibility note: Kit names can be similar across product generations, but formats are not necessarily interchangeable. Jant can help match the instrument, specimen and extraction protocol.
How to Select the Right Kit
Define the Sample
Identify the specimen, starting volume, nucleic acid target and any required pretreatment.
Match the Instrument
Select the reagent presentation designed for the Nextractor model and expected batch size.
Confirm the Application
Verify the kit, protocol and resulting nucleic acid are appropriate for the validated downstream method.
Choose a Nextractor System
Nextractor NX-48N
Flexible automated magnetic-bead extraction for one to 48 samples per run.
Nextractor NX-48S
Established automated extraction system supporting up to 48 samples per run.
Nextractor NX-Jr
Compact cartridge-based automation for lower-volume extraction workflows.
Continue the Molecular Workflow
Real-Time PCR Panels
Explore Jant standard, custom pre-plated and pharmacogenomic RT-PCR options for qualified downstream workflows.
Automated Extraction Systems
Compare automated nucleic acid extraction platforms for different throughput, sample and laboratory requirements.
Documentation and Resources
Nextractor NX-48N Brochure Nextractor NX-48S Brochure Nextractor NX-Jr Brochure Published Whole-Blood DNA Extraction StudyFrequently Asked Questions
No. Reagent presentation, kit availability and instrument protocols vary by model. Confirm the exact kit and format for the NX-48N, NX-48S or NX-Jr before ordering.
Start with the specimen and required nucleic acid type, then match those requirements to the appropriate kit family, Nextractor model and downstream method. Jant can help review these details with you.
The kits use prefilled plates, strips or individual cartridges, depending on the instrument and kit. The current Jant listing notes 48- or 96-test configurations for applicable kits, but exact packaging should be confirmed when requesting a quote.
Genolution describes its extraction kits as suitable for downstream molecular workflows, including real-time PCR. The complete process must still be validated for the selected specimen, extraction kit, assay and instrument configuration.
Intended use and regulatory status vary by kit and market. Review the current kit instructions and confirm whether the selected product is appropriate for your laboratory and jurisdiction.
Please provide the Nextractor model, specimen type, required DNA or RNA target, typical batch size, downstream method and anticipated testing volume. This helps identify the appropriate kit and package configuration.
Ordering Information
To request a quote or help selecting a compatible kit, call Jant Pharmacal at 800.676.5565
| Catalog Number | Description | Unit of Measurement |
|---|---|---|
| Varies by kit and format | Genolution DNA/RNA Extraction Kits for compatible Nextractor systems | 48 or 96 tests, depending on kit and configuration |
Please provide the Nextractor model, sample type and downstream application when requesting a quote.