Custom Gastrointestinal RT-PCR Panels

No products were found matching your selection.

Accutest® Custom Pre-Plated Gastrointestinal RT-PCR Panels

Accutest Custom Pre-Plated Gastrointestinal RT-PCR Panels allow research laboratories to select bacterial, viral and parasitic targets and create a panel around their specific molecular research workflow.

Primers and probes are pre-spotted in each well, and MasterMix is included in the current custom-panel configuration. Panels are available in 96-well and 384-well formats with clear or white plate options.

The currently published Accutest GI assay menu includes the targets shown below. Additional assays may be available upon request.

For Research Use Only. Not for use in diagnostic procedures.

17 Published GI Targets

Build from Jant's currently published bacterial, viral and parasitic gastrointestinal assay menu, with additional assays available upon request.

96- & 384-Well Formats

Custom pre-plated panels are available in 96-well and 384-well formats with clear or white plate options.

MasterMix & Internal Control

MasterMix is included, and an internal control is included in every well. RNase P is typically used, with B. atrophaeus available if desired.

Gastrointestinal Target Menu

Use the currently published Accutest GI targets as a starting point for a custom pre-plated RT-PCR configuration. Contact Jant Pharmacal if your research requires additional targets.

Bacterial Targets

  • Campylobacter
  • Clostridium difficile
  • Enteroinvasive Escherichia coli (EIEC)
  • Salmonella
  • Shiga-like Toxin E. coli stx1
  • Shiga-like Toxin E. coli stx2
  • Shigella
  • Yersinia enterocolitica

Viral Targets

  • Astrovirus
  • Human rotavirus (HRTV)
  • Human sapovirus (HSaV)
  • Norovirus G1
  • Norovirus G2
  • Pan-Adenovirus

Parasitic Targets

  • Cryptosporidium
  • Entamoeba histolytica
  • Giardia lamblia
Custom configuration: Compatible targets from different application categories may be combined on the same custom plate when the chemistry and cycling parameters are compatible. Additional assays may also be available upon request.

Panel Configuration & Ordering Information

Custom panels are produced according to the selected targets, instrument configuration and reaction format. Contact Jant Pharmacal for pricing and final configuration review.

Specification Custom Pre-Plated Configuration
Plate Formats 96-well and 384-well
Plate Options Clear or white
Primers & Probes Pre-spotted in each well
MasterMix Included
Internal Control Included in every well; RNase P is typically used, with B. atrophaeus available if desired
Positive Control Available separately at 100,000 copies/µL or 1,000 copies/µL
Negative Control Not included; nuclease-free water is recommended
Sample Input Extracted eluate
96-Well Reaction Volume Typically 20 µL; certain configurations may support 10 µL reactions
384-Well Reaction Volume 10 µL
Cycling Standard and fast cycling protocols supported
Minimum Order 50 reactions for 20 µL configurations; 100 reactions for 10 µL configurations
Typical Production Time Approximately 1 week
Shipping Dry ice
Storage –15°C to –25°C in a constant-temperature, non-frost-free freezer
Shelf Life 1 year from manufacture

Instrument & Fluorescence Compatibility

Confirmed compatible platforms include Bio-Rad, qTOWER and QuantStudio real-time PCR systems. Contact Jant Pharmacal to review compatibility with other RT-PCR instruments.

Real-Time PCR Platforms

Bio-Rad, qTOWER and QuantStudio platforms are confirmed compatible. Compatibility with other systems can be reviewed based on the instrument model and configuration.

Fluorescence Channels

Assays are assigned to fluorophores including FAM, TxRed/ROX, Cy5 and VIC/HEX/SUN according to the selected custom panel configuration.

Build the Complete RT-PCR Workflow

Compare Jant's predefined Gastrointestinal panel or review real-time PCR instrumentation and nucleic acid extraction products for your molecular research workflow.

Standard Gastrointestinal Panel

Compare your custom target requirements with Jant's predefined 17-target Standard Gastrointestinal RT-PCR Panel.

View Standard GI Panel

RT-PCR Analyzers

Review real-time PCR instrumentation for new workflows or expanded laboratory capacity.

View RT-PCR Analyzers

Nucleic Acid Extraction

Explore manual and automated extraction products for molecular research workflows.

View Extraction Solutions

Documentation and Resources

Review general instructions for Accutest® Custom Pre-Plated RT-PCR Panels, including storage, reaction setup and cycling information.

Custom Pre-Plated RT-PCR Panels — General Instructions
General storage, reaction setup and PCR cycling information
PDF

Frequently Asked Questions

Can I select the gastrointestinal targets included on my custom panel?

Yes. Custom pre-plated panels are configured around the laboratory's selected targets and instrument requirements. The currently published GI menu can be used as a starting point, and additional assays may be available upon request.

Which GI targets are currently published by Jant?

Jant's current GI menu includes 17 bacterial, viral and parasitic targets. The complete published menu is listed above.

How is this different from the Standard Gastrointestinal RT-PCR Panel?

The Standard Gastrointestinal panel uses a predefined 17-target menu. The custom offering allows the laboratory to select targets and develop a configuration around its research and instrument requirements.

Can GI targets be combined with targets from other applications?

Yes. Compatible assays from different application categories may be combined on the same custom plate when the chemistry and cycling parameters are compatible.

Which plate formats are available?

Custom panels are available in both 96-well and 384-well formats with clear or white plate options.

Are the primers and probes already on the plate?

Yes. Primers and probes are pre-spotted in the wells of the custom plate.

Is MasterMix included?

Yes. MasterMix is included with the current custom pre-plated panel configuration.

Are controls included?

An internal control is included in every well. RNase P is typically used, with B. atrophaeus available if desired. Positive controls are available separately, while nuclease-free water is recommended for the negative control.

Which real-time PCR instruments are compatible?

Bio-Rad, qTOWER and QuantStudio systems are confirmed compatible. Contact Jant Pharmacal to review compatibility with other RT-PCR instruments.

What reaction volumes are used?

384-well configurations typically use a 10 µL reaction volume. 96-well configurations typically use 20 µL reactions, although certain 96-well configurations may support 10 µL reactions.

How are custom panels shipped and stored?

Custom pre-plated panels are shipped on dry ice and should be stored at –15°C to –25°C in a constant-temperature, non-frost-free freezer.

What is the minimum order quantity?

The minimum order is 50 reactions when using a 20 µL reaction volume and 100 reactions when using a 10 µL reaction volume.

How long does production typically take?

Typical production time is approximately one week.

Are these panels intended for diagnostic use?

No. These products are offered for Research Use Only and are not for use in diagnostic procedures.

Build Your Custom Gastrointestinal RT-PCR Panel

Call 800.676.5565 or use the form below. Include your desired targets, instrument model, plate format and expected reaction volume when available.

Request Custom Panel Information

    Leave the box checked if you wish to receive occasional special offer emails, or uncheck it to decline. Don't worry, we won't spam you.