Sexual Health

No products were found matching your selection.

Accutest® Standard STI RT-PCR Panel

The Accutest Standard STI panel provides a predefined research-use menu of 12 organism targets for sexual health and sexually transmitted infection research. The menu spans bacterial, viral, yeast and protozoan targets, with RNase P (RPP30) included as an internal control.

Review the grouped target menu and available configurations below, then visit the complete product page or contact Jant’s molecular team to discuss your instrument and research workflow.

For Research Use Only. Not for use in diagnostic procedures.

12 Listed Organism Targets

A predefined menu spanning bacterial, viral, yeast and protozoan targets for molecular sexual health research.

Internal Control

RNase P (RPP30) is included as the panel’s internal control.

96-, 384-Well & Tube Formats

Available configurations include clear and white pre-spotted 96-well and 384-well plates, as well as a 100-reaction tube format.

STI Panel Target Menu

The standard menu includes 12 published organism targets plus RNase P (RPP30) as the internal control. Targets are grouped below for easier review.

Bacterial Targets

  • Chlamydia trachomatis
  • Gardnerella vaginalis
  • Haemophilus ducreyi
  • Mycoplasma genitalium
  • Mycoplasma hominis
  • Neisseria gonorrhoeae
  • Treponema pallidum
  • Ureaplasma urealyticum

Viral Targets

  • Herpes simplex virus 1 (HSV-1)
  • Herpes simplex virus 2 (HSV-2)

Yeast Target

  • Candida krusei

Protozoan Target

  • Trichomonas vaginalis
Internal control: RNase P (RPP30) is included in the standard panel menu. The headings above organize the published target list for easier page navigation and are not diagnostic result categories. Confirm the approved nomenclature, multiplex groupings and interpretation in the current product documentation.

Ordering Information

For pricing, availability and configuration review, call 800.676.5565 or submit the inquiry form below.

Catalog Number Current Product-Page Format
STI-01-C-384 Pre-spotted 384-well plate, clear
STI-01-W-384 Pre-spotted 384-well plate, white
STI-01-C-96 Pre-spotted 96-well plate, clear
STI-01-W-96 Pre-spotted 96-well plate, white
STI-01-T-384-100R Tube, 100 reactions

Please confirm the plate or tube format, instrument model, fluorescence channels and any additional control requirements with Jant before ordering.

Shipping & Storage: Panels are shipped on dry ice and should be stored at –15°C to –25°C.

Build the Complete RT-PCR Workflow

Compare related panel options, instrumentation and extraction products for the planned molecular workflow.

Women’s Health RT-PCR Panel

Review the broader Women’s Health Standard panel when the planned research menu extends beyond the predefined STI target list.

View Women’s Health Panel

RT-PCR Analyzers

Review real-time PCR instrumentation when selecting a new system or adding laboratory capacity.

View RT-PCR Analyzers

Nucleic Acid Extraction

Explore manual and automated extraction products for molecular research workflows.

View Extraction Solutions

Documentation and Resources

Accutest RT-PCR Multiplex Standard Panels Sell Sheet
Standard panel target menus and available configurations
PDF

Frequently Asked Questions

How many organism targets are included in the STI panel?

The published menu includes 12 organism targets plus RNase P (RPP30) as the internal control. RNase P is not counted as a thirteenth organism.

What types of targets are represented?

The published menu includes bacterial, viral, yeast and protozoan targets. Review the grouped menu above for the exact names.

Which formats are currently available?

Available configurations include clear and white pre-spotted 96-well and 384-well plates, as well as a 100-reaction tube format.

How does this panel differ from the Women’s Health panel?

The STI panel is a focused 12-organism menu. The Women’s Health Standard panel offers a broader predefined menu. Compare the published target lists and confirm the best fit with Jant’s molecular team.

Will the panel work with my real-time PCR instrument?

Compatibility depends on the instrument model, block or tube format and available fluorescence channels. Jant’s molecular team can review these details before ordering.

Are the MasterMix and controls included?

MasterMix is included with the panel mixes. RNase P (RPP30) is included as the internal control. Contact Jant to confirm any additional control requirements for your configuration.

How should the panel be shipped and stored?

The panel is shipped on dry ice and should be stored at –15°C to –25°C.

Is the STI panel intended for diagnostic use?

No. This product is offered for Research Use Only and is not for use in diagnostic procedures.

Need Help Confirming the Right Panel Configuration?

Call 800.676.5565 or use the form below. Include your instrument model, required targets, plate or tube format, fluorescence channels and expected research volume when available.

Request Product Information

    Leave the box checked if you wish to receive occasional special offer emails, or uncheck it to decline. Don't worry, we won't spam you.