Women’s Health

No products were found matching your selection.

Accutest® Comprehensive Women’s Health Standard RT-PCR Panel

The Accutest Women’s Health panel provides a predefined research-use menu of 28 assay targets relevant to vaginal microbiome, yeast and sexually transmitted infection research. RNase P (RPP30) is included as an internal control, for 29 total listed entries.

Review the grouped target menu and available configurations below, then visit the full product page or contact Jant’s molecular team to discuss your instrument and research workflow.

For Research Use Only. Not for use in diagnostic procedures.

28 Panel Targets + Internal Control

A predefined Women’s Health menu with 28 assay targets plus RNase P (RPP30) as the internal control.

Internal Control

RNase P (RPP30) is included as the panel’s internal control.

96-, 384-Well & Tube Formats

Available configurations include clear or white pre-spotted 96-well and 384-well plates, as well as a 100-reaction tube format.

Women’s Health Target Menu

The standard menu includes 30 published targets plus RNase P (RPP30) as the internal control. Targets are grouped below for easier review.

Vaginal Microbiome and BV-Associated Targets

    • Atopobium vaginae
    • Bacteroides fragilis
    • BVAB-2
    • Gardnerella vaginalis
    • Lactobacillus iners
    • Megasphaera type 1
    • Megasphaera type 2
    • Prevotella bivia

Yeast Targets

  • Candida albicans
  • Candida dubliniensis
  • Candida glabrata
  • Candida krusei
  • Candida parapsilosis
  • Candida tropicalis

Sexual Health–Associated Targets

  • Chlamydia trachomatis
  • Haemophilus ducreyi
  • Herpes Simplex 1
  • Herpes Simplex 2
  • Mycoplasma genitalium
  • Mycoplasma hominis
  • Neisseria gonorrhoeae
  • Treponema pallidum
  • Trichomonas vaginalis
  • Ureaplasma urealyticum

Additional Bacterial Targets

  • Enterococcus faecalis
  • Escherichia coli
  • Staphylococcus aureus
  • Streptococcus agalactiae
Internal Control: RNase P (RPP30) is included as the panel’s internal control.

Ordering Information

For pricing, availability and configuration review, call 800.676.5565 or submit the inquiry form below.

Catalog Number Current Product-Page Format
WH-01-C-384 Pre-spotted 384-well plate, clear
WH-01-W-384 Pre-spotted 384-well plate, white
WH-01-C-96 Pre-spotted 96-well plate, clear
WH-01-W-96 Pre-spotted 96-well plate, white
WH-01-T-384-100R Tube, 100 reactions

Please confirm the plate or tube format, instrument model, fluorescence channels and any additional control requirements with Jant before ordering.

Shipping & Storage: Panels are shipped on dry ice and should be stored at –15°C to –25°C.

Build the Complete RT-PCR Workflow

Compare a focused STI menu and review instrumentation or extraction products for the planned molecular workflow.

Standard STI RT-PCR Panel

Compare the broader Women’s Health target menu with Jant’s focused Standard STI panel.

View Standard STI Panel

RT-PCR Analyzers

Review real-time PCR instrumentation when selecting a new system or adding laboratory capacity.

View RT-PCR Analyzers

Nucleic Acid Extraction

Explore manual and automated extraction products for molecular research workflows.

View Extraction Solutions

Documentation and Resources

Accutest RT-PCR Multiplex Standard Panels Sell Sheet
Standard panel target menus and available configurations
PDF

Frequently Asked Questions

How many targets are included in the Women’s Health panel?

The panel includes 28 assay targets plus RNase P (RPP30) as the internal control, for 29 total listed entries.

What target groups are represented?

The published menu includes vaginal microbiome and BV-associated targets, Candida species, sexual-health-associated targets and additional bacterial targets. Review the grouped menu above for the exact names.

How is this different from the Standard STI RT-PCR Panel?

The Women’s Health panel provides a broader 30-target menu that includes vaginal microbiome and yeast targets in addition to sexual-health-associated targets. The Standard STI panel offers a more focused STI target menu.

Which formats are currently available?

Available configurations include clear and white pre-spotted 96-well and 384-well plates, as well as a 100-reaction tube format.

Will the panel work with my real-time PCR instrument?

Compatibility depends on the instrument model, block or tube format and available fluorescence channels. Jant’s molecular team can review these details before ordering.

Are the MasterMix and controls included?

MasterMix is included with the panel mixes. RNase P (RPP30) is included as the internal control. Contact Jant to confirm any additional control requirements for your configuration.

How should the panel be shipped and stored?

The panel is shipped on dry ice and should be stored at –15°C to –25°C.

Is the Women’s Health panel intended for diagnostic use?

No. This product is offered for Research Use Only and is not for use in diagnostic procedures.

Need Help Confirming the Right Panel Configuration?

Call 800.676.5565 or use the form below. Include your instrument model, required targets, plate or tube format, fluorescence channels and expected research volume when available.

Request Product Information

    Leave the box checked if you wish to receive occasional special offer emails, or uncheck it to decline. Don't worry, we won't spam you.