Product Overview
The Omega Bio-tek MagBinder® Fit24 Nucleic Acid Purification System automates magnetic-bead DNA and RNA purification for one to 24 samples per run. Its 24 magnetic rods transfer particles through 5 mL or 10 mL reagent cartridges, supporting both lower- and higher-volume sample workflows on a compact benchtop platform.
Laboratories can use prefilled MB Fit24™ cartridges with preloaded scripts or develop qualified protocols for compatible Omega Bio-tek Mag-Bind® kits. A 7-inch touchscreen provides access to saved protocols, while USB import, editable parameters and onboard storage support laboratories with different extraction requirements.
Regulatory note: Omega Bio-tek describes research-use and CE-IVD-marked configurations for markets that accept CE marking. Confirm the exact instrument configuration, reagent kit, intended use and regulatory status required for your laboratory and jurisdiction. CE-IVD marking does not establish U.S. FDA clearance.
1–24 Samples
Process a partial or full batch without committing to a high-throughput automation platform.
50 µL–10 mL Input
Accommodates a broad published sample-volume range using 5 mL or 10 mL reagent cartridges.
Prefilled or Programmable
Use prefilled MB Fit24 cartridges and scripts or create qualified protocols for compatible Mag-Bind kits.
Key Features
- Automated magnetic-bead purification of DNA and RNA
- Flexible throughput from one to 24 samples per run
- Published sample-volume range of 50 µL to 10,000 µL
- Compatible with 5 mL and 10 mL reagent cartridges and 2 mL elution tubes
- Prefilled MB Fit24 cartridge options with preloaded instrument scripts
- Programmable protocols for compatible Omega Bio-tek Mag-Bind kits
- 7-inch touchscreen with three shortcut keys
- Stores up to 100 protocols, with up to eight available from the shortcut screen
- USB protocol import and onboard protocol editing
- Heat block operating from ambient temperature to 100°C
- UV decontamination light and internal exhaust fan
- Compact benchtop footprint for laboratories that do not require 96-sample automation
Product Specifications
| Catalog Number | B1-001-24 |
|---|---|
| Model | MagBinder Fit24 |
| Purification Principle | Magnetic bead-based processing |
| Throughput | 1–24 samples per run |
| Published Sample-Volume Range | 50–10,000 µL; actual volume depends on the selected kit and protocol |
| Plasticware | 5 mL or 10 mL reagent cartridges with 2 mL elution tubes |
| Heat Block | Ambient temperature to 100°C |
| Temperature Accuracy | ±1°C |
| User Interface | 7-inch touchscreen, three shortcut keys; mouse support available |
| Protocol Storage | Up to 100 protocols; up to eight on the shortcut screen |
| Protocol Import | Standard USB |
| Protocol Management | Create, edit, delete and save protocols |
| Decontamination | UV light |
| Exhaust | Internal fan |
| Maximum Input Power | 450 W |
| Dimensions | 400 mm W × 530 mm D × 480 mm H |
| Weight | 34 kg |
Specifications are based on the current Jant-hosted manufacturer literature. Kit-specific sample preparation, run time, input and elution volumes vary.
Magnetic-Bead Purification Workflow
Select the Protocol
Choose the qualified reagent kit and instrument script for the specimen and downstream method.
Prepare and Load
Complete any required offline lysis, then load the samples, cartridges, tip comb and elution tubes.
Purify and Collect
The magnetic rods automate particle transfer through binding, wash and elution steps.
This is a general workflow summary. Follow the current instrument manual, kit instructions and laboratory procedures.
Prefilled MB Fit24 Reagent Options
Jant currently lists two prefilled cartridge kits developed specifically for the MagBinder Fit24.
MB Fit24 Blood & Tissue DNA Kit
Prefilled workflow for DNA purification from supported blood, saliva, swab, cultured-cell and fresh or frozen tissue samples.
Catalog: B6399-5-48PF
Unit: 48 cartridges
MB Fit24 cfDNA Kit
Prefilled workflow for circulating cell-free DNA purification from up to 4 mL of supported plasma or serum samples.
Catalog: B3298-10-48PF
Unit: 48 cartridges
Need a different sample type? Browse Jant magnetic-bead extraction reagents and confirm Fit24 protocol compatibility before ordering.
Build the Complete Molecular Workflow
Magnetic-Bead Reagents
Review Jant’s available extraction chemistries and confirm instrument and protocol compatibility.
Real-Time PCR
Connect nucleic acid purification with Jant standard, custom and pharmacogenomic RT-PCR options.
NGS Sample Preparation
Explore extraction and sample-preparation products for qualified next-generation sequencing workflows.
Product Videos
System Introduction
Unboxing and Setup
Additional Instructional Videos
Documentation and Resources
Product Documents
MagBinder Fit24 Brochure Operation Manual Quick Start GuideApplication Notes
DNA Purification from 2 mL Whole Blood DNA Extraction from Whole Blood and Saliva Automated cfDNA Extraction Workflow Rare Variant Detection in cfDNA by ddPCR cfDNA Blood Collection Tube CompatibilityFrequently Asked Questions
The instrument processes from one to 24 samples per run. The selected reagent kit and protocol determine the supported sample type, input volume and run time.
Jant currently lists the MB Fit24 Blood & Tissue DNA Kit and the MB Fit24 cfDNA Kit. Both are supplied as 48-cartridge configurations. Confirm current availability and the appropriate kit for your specimen before ordering.
The manufacturer describes the platform as programmable for compatible Mag-Bind kits. This may require reagent dispensing, protocol setup and workflow qualification. Confirm protocol availability and plasticware requirements for the specific kit.
The published instrument range is 50 µL to 10 mL. Actual supported volume depends on the kit, cartridge, offline preparation and protocol. For example, the MB Fit24 cfDNA Kit supports up to 4 mL of plasma or serum.
Omega Bio-tek application materials describe downstream PCR, qPCR and NGS workflows for selected kits. The complete extraction and downstream process must be validated for the specimen, reagent, assay and instrument configuration used by the laboratory.
Omega Bio-tek describes research-use and CE-IVD-marked configurations. CE-IVD use is limited to applicable markets and does not mean the system is FDA-cleared in the United States. Confirm the exact configuration and intended use before purchase.
Ordering Information
To place an order or request information, call Jant Pharmacal at 800.676.5565
| Catalog Number | Description | Unit of Measurement |
|---|---|---|
| B1-001-24 | Omega Bio-tek MagBinder Fit24 Nucleic Acid Purification System | 1 instrument |
Extraction kits, cartridges, tip combs, elution tubes and other consumables are quoted separately unless specifically included.