Product Overview
The Allsheng Auto-Pure 96 Nucleic Acid Purification System is an automated magnetic-bead platform for research-use DNA and RNA extraction. The system uses a 96-well deep-well plate and 96 magnetic rod tips to process from 1 to 96 samples in a run.
With a working volume of 50–1,000 µL per well, the Auto-Pure 96 supports configurable magnetic-bead purification workflows for compatible biological sample types. The manufacturer describes typical extraction times of approximately 30–60 minutes for the Auto-Pure 96/48/24 product family; actual run time, sample compatibility and performance depend on the selected extraction kit and validated protocol.
An open, editable protocol interface, integrated heating, automated plate-position recognition and contamination-control features help laboratories standardize research workflows while retaining flexibility for reagent optimization. This product is for research use only and is not presented as an in vitro diagnostic device.
1–96 Samples per Run
Scale a run from one sample to a full 96-well deep-well plate.
50–1,000 µL
Supports magnetic-bead purification protocols within the listed per-well working-volume range.
Open, Editable Protocols
Create, edit, save and manage programs for compatible magnetic-bead reagents.
Key Features
- Automated magnetic-bead separation for research-use DNA and RNA purification
- Flexible throughput from 1 to 96 samples per run
- 50–1,000 µL working volume per well
- 96-well deep-well plate and 96-position magnetic rod-tip format
- Open software for creating and editing magnetic-bead extraction protocols
- Seven-inch touchscreen with three shortcut buttons and optional mouse control
- Eight preset program groups and storage for up to 100 programs
- Editable mixing, binding and magnetic-capture modes for protocol optimization
- Integrated lysis and elution temperature control
- Automatic recognition of eight plate positions
- LED interior lighting for observing instrument status
- USB, Ethernet and Wi-Fi connectivity
- Built-in SD-card data storage
- UV-light and disposable-consumable features designed to reduce contamination risk between runs
Automated Magnetic-Bead Workflow
The exact preparation, reagent volumes, mixing sequence, wash steps and elution conditions are defined by the selected extraction kit and validated laboratory protocol.
1. Prepare
Load prepared samples, compatible magnetic-bead reagents, the 96-well deep-well plate and magnetic rod tips according to the kit protocol.
2. Bind
The programmed mixing sequence brings magnetic particles into contact with the lysed sample so nucleic acids can bind.
3. Wash
Magnetic rods collect and transfer the particles through the programmed wash steps to remove unwanted material.
4. Elute
Purified DNA or RNA is released into the elution solution for an appropriately validated downstream research workflow.
Technical Specifications
| Model | Auto-Pure 96 |
|---|---|
| Jant Catalog Number | AS1706000 |
| Working Principle | Magnetic-bead method using magnetic rods and a center rotary table |
| Throughput | 1–96 samples per run |
| Processing Volume | 50–1,000 µL per well |
| Primary Consumables | 96-well deep-well plate and 96 magnetic rod tips |
| Typical Extraction Time | Approximately 30–60 minutes, depending on the extraction kit and protocol |
| Lysis Temperature | Room temperature to 120°C, as listed in the manufacturer brochure |
| Elution Temperature | Room temperature to 120°C, as listed in the manufacturer brochure |
| Mixing | Editable mixing modes |
| User Interface | Seven-inch touchscreen, three shortcut buttons and optional mouse |
| Program Capacity | Eight preset program groups; up to 100 programs stored |
| Program Management | New, edit, delete and save as |
| Connectivity | USB, Ethernet and Wi-Fi |
| Data Storage | Built-in SD card |
| Interior Lighting | LED |
| Contamination-Control Features | UV light, disposable consumables, drip-control design and fan exhaust |
| Maximum Input Power | 300 W |
| Dimensions | 56 × 62 × 50 cm (dimension order is not identified in the brochure) |
| Weight | 54 kg (approximately 119 lb) |
| Use Classification | Research use only |
Specifications are based on the Jant-hosted Allsheng Auto-Pure Series brochure. Confirm the current instrument configuration, electrical requirements, operating manual and included accessories with Jant before purchase.
Consumables and Workflow Configuration
Instrument Consumables
- 96-well deep-well plate
- 96-position magnetic tip comb
- 96-well elution plate, when required by the selected workflow
- Compatible magnetic-bead extraction reagents
Confirm Before Implementation
- Sample type and supported input amount
- Extraction chemistry and magnetic-particle compatibility
- Plate map, reagent volumes and working-volume limits
- Protocol steps, heating conditions and run time
- Elution volume and downstream quality requirements
- Laboratory validation and research-use requirements
Explore Reagents and Downstream Molecular Workflows
Use the links below to review Jant’s research-use magnetic-bead reagents, automated extraction systems and Real-Time PCR offerings.
Browse Magnetic Bead Reagents Explore Automated Extraction Systems Explore Real-Time PCR Explore NGS Sample PreparationThese category links are provided to help laboratories explore related products. They do not establish compatibility with the Auto-Pure 96. Confirm the extraction kit, sample matrix, plate format, working volume, magnetic-particle chemistry, protocol, intended use and downstream validation requirements before implementation.
Important Product Information
- The Auto-Pure 96 on this Jant page is presented for research use only and is not presented as an in vitro diagnostic device.
- The instrument is designed for automated DNA and RNA purification with compatible magnetic-bead extraction kits; it does not by itself define a validated sample type, yield, purity or downstream application.
- The 50–1,000 µL specification is the instrument’s listed per-well processing volume, not a universal specimen-input volume.
- Compatible sample types, reagent volumes, preparation steps and performance depend on the selected extraction kit and protocol.
- UV light, disposable consumables and drip-control features are intended to reduce contamination risk; they do not guarantee the absence of cross-contamination.
- Follow the current instrument manual, reagent instructions, laboratory biosafety procedures and waste-disposal requirements.
- Confirm current model designation, availability, electrical requirements, included accessories, installation, training, warranty and service coverage when requesting a quote.
Documentation and Resources
Review the product-family brochure for Auto-Pure 96 specifications and contact Jant for the current operating manual, configuration details and quotation.
Auto-Pure Series Brochure Allsheng Download CenterFrequently Asked Questions
The Auto-Pure 96 is an automated magnetic-bead nucleic acid purification system for research-use DNA and RNA extraction. It uses a 96-well deep-well plate and 96 magnetic rod tips to process from 1 to 96 samples per run.
No. The instrument on this Jant page is presented for research use only and is not presented as an in vitro diagnostic device. Laboratories should follow the labeling and regulatory status of the specific instrument, reagents and downstream application they implement.
The manufacturer brochure lists flexible throughput from 1 to 96 samples per run.
The listed working-volume range is 50–1,000 µL per well. This is not a universal specimen-input range; the extraction kit and validated protocol determine the appropriate sample and reagent volumes.
The manufacturer describes approximately 30–60 minutes for the Auto-Pure 96/48/24 product family. Actual run time depends on the selected reagent kit and protocol.
The manufacturer brochure references tissues, blood, body fluids and other biological materials across compatible workflows. A particular sample type should be listed in the selected magnetic-bead kit instructions and verified with the instrument protocol; the instrument page alone does not establish compatibility.
Yes. The brochure describes open, editable software with functions to create, edit, delete and save programs. It lists eight preset program groups and storage for up to 100 programs.
The instrument uses a 96-well deep-well plate and a 96-position magnetic rod-tip comb. A compatible elution plate and magnetic-bead extraction reagents may also be required by the selected workflow.
The system includes disposable consumables, UV light and drip-control features designed to reduce contamination risk. No feature should be interpreted as a guarantee that cross-contamination cannot occur; good laboratory practices, environmental controls and workflow validation remain necessary.
Compatibility must be confirmed for the specific kit, sample matrix, plate format, working volume, magnetic-particle chemistry and protocol. The link to Jant’s magnetic-bead reagent category is a discovery aid and does not by itself establish compatibility.
Purified DNA or RNA may be suitable for an appropriately validated downstream research workflow. Suitability depends on the extraction chemistry, sample type, nucleic-acid quality, elution conditions and requirements of the Real-Time PCR or NGS method.
Confirm the current Auto-Pure 96 model designation, intended research workflow, sample types, daily throughput, extraction kits, consumables, electrical requirements, included accessories, installation, training, warranty and service coverage.
Ordering Information
To confirm current availability or request a quote, call Jant Pharmacal at 800.676.5565
| Catalog Number | Description | Throughput | Unit of Measurement |
|---|---|---|---|
| AS1706000 | Allsheng Auto-Pure 96 Nucleic Acid Purification System | 1–96 samples per run | Each |
Confirm the exact model, included accessories, compatible extraction kits, consumables, electrical requirements, installation, training, warranty and service coverage when requesting a quote.