Standard Multiplex RT-PCR Panel
Accutest® Standard STI RT-PCR Panel
A predefined multiplex Research Use Only panel featuring 12 organism targets plus RNase P (RPP30) as the internal control.
The Standard STI menu includes bacterial, viral, yeast and protozoan targets for molecular sexual health research.
Organism Targets
A focused predefined Standard STI research menu.
Plate Formats
Clear or white pre-spotted plates plus a tube configuration.
MasterMix
MasterMix is included with the panel mixes.
Target Menu
Standard STI Assay Menu
The panel includes 12 organism targets.
RNase P (RPP30) is included separately as the internal control
and is not counted as a thirteenth organism.
Bacterial Targets
- Chlamydia trachomatis
- Gardnerella vaginalis
- Haemophilus ducreyi
- Mycoplasma genitalium
- Mycoplasma hominis
- Neisseria gonorrhoeae
- Treponema pallidum
- Ureaplasma urealyticum
Viral Targets
- Herpes simplex virus 1 (HSV-1)
- Herpes simplex virus 2 (HSV-2)
Yeast Target
- Candida krusei
Protozoan Target
- Trichomonas vaginalis
Internal Control:
RNase P (RPP30) is included as the panel’s internal control.
Flexible Configuration
Choose the Format for Your Workflow
The Standard STI panel is available in multiple plate and tube configurations for different molecular research workflows.
Pre-Spotted Plate Formats
- 96-well plate — clear
- 96-well plate — white
- 384-well plate — clear
- 384-well plate — white
- Primers and probes pre-spotted in plate configurations
Tube Configuration
- 100-reaction tube format
- MasterMix included with panel mixes
- Alternative to the pre-spotted plate configuration
Technical Information
Panel Specifications
Review the standard configuration below and confirm instrument-specific
requirements with Jant before ordering.
| Specification | Standard STI Panel |
|---|---|
| Organism Targets | 12 |
| Internal Control | RNase P (RPP30) |
| MasterMix | Included |
| Plate Formats | 96-well and 384-well |
| Plate Options | Clear or white |
| Tube Format | 100 reactions |
| 96-Well Reaction Volume | 20 µL |
| 384-Well Reaction Volume | 10 µL |
| Cycling | Standard and fast cycling protocols supported |
| Shipping | Dry ice |
| Storage | –15°C to –25°C |
| Use | Research Use Only |
Workflow
Standard RT-PCR Setup
Final setup should follow the current product documentation and
instrument-specific requirements.
Prepare the Reaction
Prepare the included MasterMix according to the applicable panel instructions
and selected configuration.
Add Template
Add the appropriate nucleic-acid template according to the current research
workflow and product instructions.
Seal & Prepare
Seal the selected reaction vessel, mix as required and prepare it
for amplification.
Run RT-PCR
Run the appropriate cycling protocol on a compatible real-time PCR instrument.
Ordering Information
Available Configurations
Choose the plate or tube configuration that matches your research workflow.
| Catalog Number | Format |
|---|---|
| STI-01-C-384 | Pre-spotted 384-well plate, clear |
| STI-01-W-384 | Pre-spotted 384-well plate, white |
| STI-01-C-96 | Pre-spotted 96-well plate, clear |
| STI-01-W-96 | Pre-spotted 96-well plate, white |
| STI-01-T-384-100R | Tube format, 100 reactions |
Before ordering:
Confirm the plate or tube format, instrument model, fluorescence channels
and any additional control requirements with Jant Pharmacal.
Focused STI Panel or Broader Women’s Health Panel?
Compare the predefined menus based on the targets required for your research workflow.
Standard STI Panel
A focused predefined sexual health menu containing 12 organism targets.
- 12 organism targets
- RNase P (RPP30) internal control
- Bacterial, viral, yeast and protozoan targets
- 96-/384-well and tube formats
Standard Women’s Health Panel
A broader predefined menu that adds vaginal microbiome, BV-associated,
Candida and additional bacterial targets.
Frequently Asked Questions
Standard STI RT-PCR Panel FAQ
How many organism targets are included?
The Standard STI panel includes 12 organism targets plus RNase P (RPP30)
as the internal control. RNase P is not counted as a thirteenth organism.
What types of targets are represented?
The predefined menu includes bacterial, viral, yeast and protozoan targets.
Is RNase P included?
Yes. RNase P (RPP30) is included as the panel’s internal control.
Is MasterMix included?
Yes. MasterMix is included with the panel mixes.
Which formats are available?
Available configurations include clear and white pre-spotted 96-well and
384-well plates, as well as a 100-reaction tube format.
What reaction volumes are used?
The standard configuration uses a 20 µL reaction volume for 96-well formats
and a 10 µL reaction volume for 384-well formats.
How does this panel differ from the Women’s Health panel?
The Standard STI panel provides a focused 12-organism target menu.
The Standard Women’s Health panel provides a broader predefined menu
that includes additional vaginal microbiome, yeast and bacterial targets.
How is the panel shipped and stored?
The panel is shipped on dry ice and should be stored at –15°C to –25°C.
Is this panel intended for diagnostic use?
No. The Accutest® Standard STI RT-PCR Panel is offered for Research Use Only
and is not for use in diagnostic procedures.
Request Information
Need Help Selecting an STI RT-PCR Configuration?
Complete the form below and Jant Pharmacal can help review the appropriate
format and instrument requirements for your research workflow.
You can also call
800.676.5565.








