Standard Multiplex RT-PCR Panel
Accutest® Standard COVID/Flu/RSV RT-PCR Panel
A targeted multiplex Research Use Only panel combining SARS-CoV-2, Influenza A, Influenza B and RSV A & B in one predefined RT-PCR menu.
RNase P is included as the endogenous internal control. The panel is available in clear or white 96-well and 384-well pre-spotted plates, as well as a 100-reaction tube format.
Targeted Respiratory Menu
A predefined viral target combination for respiratory molecular research.
Plate Formats
Clear or white pre-spotted plates plus a tube configuration.
MasterMix
MasterMix is included with the panel mixes.
Target Menu
COVID/Flu/RSV Viral Targets
The Standard COVID Combo panel combines four respiratory viral target groups
with RNase P as the endogenous internal control.
SARS-CoV-2
Respiratory viral target
Influenza A
Respiratory viral target
Influenza B
Respiratory viral target
RSV A & B
Respiratory viral target
Endogenous Internal Control:
RNase P is included in the predefined panel menu.
Flexible Configuration
Choose the Format for Your Workflow
The Standard COVID/Flu/RSV panel is available in multiple plate and tube
configurations for different molecular research workflows.
Pre-Spotted Plate Formats
- 96-well plate — clear
- 96-well plate — white
- 384-well plate — clear
- 384-well plate — white
- Primers and probes pre-spotted in plate configurations
Tube Configuration
- 100-reaction tube format
- MasterMix included with panel mixes
- Alternative to a pre-spotted plate configuration
Technical Information
Panel Specifications
Review the standard configuration below and confirm instrument-specific
requirements with Jant before ordering.
| Specification | Standard COVID/Flu/RSV Panel |
|---|---|
| Viral Target Menu | SARS-CoV-2, Influenza A, Influenza B, RSV A & B |
| Internal Control | RNase P |
| MasterMix | Included |
| Plate Formats | 96-well and 384-well |
| Plate Options | Clear or white |
| Tube Format | 100 reactions |
| 96-Well Reaction Volume | 20 µL |
| 384-Well Reaction Volume | 10 µL |
| Cycling | Standard and fast cycling protocols supported |
| Shipping | Dry ice |
| Storage | –15°C to –25°C |
| Use | Research Use Only |
Workflow
Standard RT-PCR Setup
Final setup should follow the current product documentation and
instrument-specific requirements.
Prepare the Reaction
Prepare the included MasterMix according to the applicable panel instructions
and selected configuration.
Add Template
Add the appropriate nucleic-acid template according to the current research
workflow and product instructions.
Seal & Prepare
Seal the selected reaction vessel, mix as required and prepare the plate
or tubes for amplification.
Run RT-PCR
Run the appropriate cycling protocol on a compatible real-time PCR instrument.
Ordering Information
Available Configurations
Choose the plate or tube configuration that matches your research workflow.
| Catalog Number | Format |
|---|---|
| CFR-01-C-384 | Pre-spotted 384-well plate, clear |
| CFR-01-W-384 | Pre-spotted 384-well plate, white |
| CFR-01-C-96 | Pre-spotted 96-well plate, clear |
| CFR-01-W-96 | Pre-spotted 96-well plate, white |
| CFR-01-T-384-100R | Tube format, 100 reactions |
Before ordering:
Confirm the plate or tube format, instrument model, fluorescence channels
and any additional control requirements with Jant Pharmacal.
Targeted COVID Combo or Broader Respiratory Panel?
Choose the focused COVID/Flu/RSV menu or a broader Standard Respiratory panel
based on your research requirements.
COVID/Flu/RSV Panel
A focused predefined menu covering major seasonal respiratory viral targets.
- SARS-CoV-2
- Influenza A
- Influenza B
- RSV A & B
- RNase P internal control
Standard Respiratory Panels
Broader predefined respiratory target menus for research workflows requiring
additional respiratory organisms.
Frequently Asked Questions
Standard COVID/Flu/RSV RT-PCR Panel FAQ
Which targets are included?
The predefined target menu includes SARS-CoV-2, Influenza A, Influenza B
and RSV A & B. RNase P is included as the endogenous internal control.
Is MasterMix included?
Yes. MasterMix is included with the panel mixes.
Which formats are available?
Available configurations include clear and white pre-spotted 96-well and
384-well plates, as well as a 100-reaction tube format.
What reaction volumes are used?
The standard configuration uses a 20 µL reaction volume for 96-well formats
and a 10 µL reaction volume for 384-well formats.
Are standard and fast cycling protocols supported?
Yes. Standard and fast cycling protocols are supported. Confirm the appropriate
protocol for the selected configuration and instrument before use.
How is the panel shipped and stored?
The panel is shipped on dry ice and should be stored at –15°C to –25°C.
Is this panel intended for diagnostic use?
No. The Accutest® Standard COVID/Flu/RSV RT-PCR Panel is offered for
Research Use Only and is not for use in diagnostic procedures.
Request Information
Need Help Selecting a COVID/Flu/RSV RT-PCR Configuration?
Complete the form below and Jant Pharmacal can help review the appropriate
format and instrument requirements for your research workflow.
You can also call