Accutest® Custom Pre-Plated Antibiotic Resistance RT-PCR Panels
Accutest Custom Pre-Plated Antibiotic Resistance RT-PCR Panels allow research laboratories to select antimicrobial-resistance targets according to their specific testing workflow. Primers and probes are pre-spotted in each well, with MasterMix included in the current custom-panel configuration.
Panels are available in 96-well and 384-well formats with clear or white plate options. Jant Pharmacal can configure the selected assays for compatible real-time PCR systems and review instrument, fluorescence-channel and reaction-volume requirements with your laboratory.
Custom Target Selection
Select resistance targets based on your research requirements, including compatible assays from other custom panel categories when appropriate.
96- & 384-Well Formats
Custom pre-plated panels are available in 96-well and 384-well formats with clear or white plate options.
MasterMix & Internal Control
MasterMix is included, and an internal control is included in every well. RNase P is typically used, with B. atrophaeus available if desired.
Antibiotic Resistance Target Menu
Select targets from the available antibiotic-resistance assay menu to create a custom pre-plated RT-PCR configuration.
- ampC
- ACT-1/3/2/34
- CTX-M-1/2/9/8
(bla_CTX-M-3, blaCTX-M-9, blaCTX-M-35, blaCTX-M-63) - dfrA1
- dfrA5
- ErmA
- ErmB
- ErmC
- GES
- IMP-1
- IMP-2
- KPC
- mecA
- mecC
- NDM
- OXA-1
- OXA-23
- OXA-48
- OXA-58
- QnrA
- QnrS
- SHV
- sul1
- TEM
- tetM
- VanA
- VanB
Panel Configuration & Ordering Information
Custom panels are produced according to the selected targets, instrument configuration and reaction format. Contact Jant Pharmacal for pricing and final configuration review.
| Specification | Custom Pre-Plated Configuration |
|---|---|
| Plate Formats | 96-well and 384-well |
| Plate Options | Clear or white |
| Primers & Probes | Pre-spotted in each well |
| MasterMix | Included |
| Internal Control | Included in every well; RNase P is typically used, with B. atrophaeus available if desired |
| Positive Control | Available separately at 100,000 copies/µL or 1,000 copies/µL |
| Negative Control | Not included; nuclease-free water is recommended |
| Sample Input | Extracted eluate |
| 96-Well Reaction Volume | Typically 20 µL; certain configurations may support 10 µL reactions |
| 384-Well Reaction Volume | 10 µL |
| Cycling | Standard and fast cycling protocols supported |
| Minimum Order | 50 reactions for 20 µL configurations; 100 reactions for 10 µL configurations |
| Typical Production Time | Approximately 1 week |
| Shipping | Dry ice |
| Storage | –15°C to –25°C in a constant-temperature, non-frost-free freezer |
| Shelf Life | 1 year from manufacture |
Instrument & Fluorescence Compatibility
Confirmed compatible platforms include Bio-Rad, qTOWER and QuantStudio real-time PCR systems. Contact Jant Pharmacal to review compatibility with other RT-PCR instruments.
Real-Time PCR Platforms
Bio-Rad, qTOWER and QuantStudio platforms are confirmed compatible. Compatibility with other systems can be reviewed based on the instrument model and configuration.
Fluorescence Channels
Assays are assigned to fluorophores including FAM, TxRed/ROX, Cy5 and VIC/HEX/SUN according to the selected custom panel configuration.
Build the Complete RT-PCR Workflow
Review other custom panel options, real-time PCR instrumentation and nucleic acid extraction solutions for your molecular workflow.
Custom Pre-Plated Panels
Explore other application areas and create custom target combinations for research workflows.
View Custom PanelsRT-PCR Analyzers
Review real-time PCR instrumentation for new workflows or expanded laboratory capacity.
View RT-PCR AnalyzersNucleic Acid Extraction
Explore manual and automated extraction products for molecular research workflows.
View Extraction SolutionsDocumentation and Resources
Review general instructions for Accutest® Custom Pre-Plated RT-PCR Panels, including storage, reaction setup and cycling information.
Frequently Asked Questions
Can I select the targets included on my custom panel?
Yes. Jant Pharmacal can configure the panel according to the selected assays. Compatible targets from different application categories may also be combined when they use the same chemistry and cycling parameters.
Which plate formats are available?
Custom panels are available in both 96-well and 384-well formats with clear or white plate options.
Are the primers and probes already on the plate?
Yes. Primers and probes are pre-spotted in the wells of the custom plate.
Is MasterMix included?
Yes. MasterMix is included with the current custom pre-plated panel configuration.
Are controls included?
An internal control is included in every well. RNase P is typically used, with B. atrophaeus available if desired. Positive controls are available separately, while nuclease-free water is recommended for the negative control.
Which real-time PCR instruments are compatible?
Bio-Rad, qTOWER and QuantStudio systems are confirmed compatible. Contact Jant Pharmacal to review compatibility with other RT-PCR instruments.
What reaction volumes are used?
384-well configurations typically use a 10 µL reaction volume. 96-well configurations typically use 20 µL reactions, although certain 96-well configurations may support 10 µL reactions.
How are custom panels shipped and stored?
Custom pre-plated panels are shipped on dry ice and should be stored at –15°C to –25°C in a constant-temperature, non-frost-free freezer.
What is the minimum order quantity?
The minimum order is 50 reactions when using a 20 µL reaction volume and 100 reactions when using a 10 µL reaction volume.
How long does production typically take?
Typical production time is approximately one week.
Are these panels intended for diagnostic use?
No. These products are offered for Research Use Only and are not for use in diagnostic procedures.
Build Your Custom RT-PCR Panel
Call 800.676.5565 or use the form below. Include your desired targets, instrument model, plate format and expected reaction volume when available.