Product Overview
The NanoEntek FREND System (F10) is a compact benchtop analyzer for quantitative fluorescence immunoassay testing. The system uses single-use microfluidic assay cartridges to combine sample movement, reaction and fluorescence measurement in a cartridge-based format.
Jant lists FREND cartridges for PSA Plus, thyroid-stimulating hormone (TSH), Free T4, testosterone and vitamin D. Each assay has its own intended use, accepted specimen types, preparation steps, accessories, processing time and regulatory requirements. Laboratories should review the current assay instructions before implementation.
This page describes the original FREND System model F10. It should not be confused with the newer FREND 2.0 platform, which has different hardware and software specifications. Contact Jant Pharmacal to confirm the available analyzer, assay menu, included components, installation and support options.
Microfluidic Cartridge Format
Single-use assay cartridges support a contained, assay-specific workflow with limited hands-on analyzer operation.
Quantitative Fluorescence Detection
The analyzer reads fluorescence generated within the cartridge and reports a quantitative, assay-dependent result.
Compact Benchtop System
A 7-inch touchscreen and approximately 3 kg instrument weight support laboratories where benchtop space is limited.
Key Features
- Compact fluorescence immunoassay analyzer for use with FREND microfluidic cartridges
- Quantitative, assay-specific results displayed on the analyzer
- 7-inch touchscreen user interface
- Small benchtop footprint of approximately 240 × 260 × 175 mm
- Approximate analyzer weight of 3 kg (6.6 lb)
- Cartridge-based workflow designed to reduce manual analyzer steps
- Lot-specific assay information supplied through the applicable code chip
- Dedicated quality-control cartridge for instrument checks
- Optional assay-processing accessories available for workflows that require pretreatment
- Rapid analyzer readout, with total workflow time determined by the selected assay and required preparation
A Cartridge-Based Immunoassay Workflow
1. Review the Assay Instructions
Confirm the accepted specimen, storage conditions, preparation steps, accessories and quality-control requirements for the selected assay.
2. Prepare the Sample
Prepare the patient sample exactly as directed. Some assays require additional pretreatment, incubation or heating steps.
3. Load the Cartridge
Apply the prepared specimen to the correct FREND cartridge and insert the cartridge into the analyzer as instructed.
4. Review the Result
The system reads the cartridge and displays the quantitative result. Interpret and report results under the current assay labeling and laboratory procedures.
FREND Assay Cartridges Listed by Jant
The following cartridges are included in Jant’s current product listing. Availability and regulatory status should be confirmed before ordering.
| Assay | Jant Catalog Number | Kit Size | Workflow Planning |
|---|---|---|---|
| PSA Plus | FRPS025 | 25 tests/kit | Quantitative assay; follow the current instructions for specimen type, measuring range and clinical limitations. |
| TSH | FRTS025 | 25 tests/kit | Quantitative thyroid-stimulating hormone assay for prescription clinical-laboratory use under current labeling. |
| Free T4 | FRT4020 | 20 tests/kit | Quantitative thyroid assay; confirm current specimen, preparation, quality-control and reporting requirements. |
| Testosterone | FRTE020 | 20 tests/kit | Requires assay-specific sample pretreatment and heating. U.S. labeling does not identify this assay for point-of-care settings. |
| Vitamin D | FRVD020 | 20 tests/kit | Requires assay-specific pretreatment. Confirm the FREND Auto Processor and other required materials; U.S. labeling does not identify this assay for point-of-care settings. |
Assays do not share a universal specimen type, preparation procedure, processing time, measuring range or CLIA classification. Use only the current assay instructions and confirm U.S. regulatory status and availability with Jant Pharmacal.
Technical Specifications
| Specification | FREND System (F10) |
|---|---|
| Analyzer Type | Compact microfluidic fluorescence immunoassay analyzer |
| Test Format | Single-use, assay-specific FREND cartridges |
| User Interface | 7-inch touchscreen |
| Dimensions (W × L × H) | 240 × 260 × 175 mm |
| Weight | Approximately 3 kg (6.6 lb) |
| Electrical Input | 100–240 V, 1.7 A, 50/60 Hz |
| DC Output | 12 V, 3.33 A |
| Operating Conditions | 15–30°C; 10–80% relative humidity |
| Storage Conditions | 15–30°C; 10–80% relative humidity |
| Result and Test Time | Quantitative result; preparation steps and total workflow time vary by assay |
Specifications describe the original FREND System model F10 and should be confirmed in the current quotation and product documentation.
Accessories and Workflow Materials
FREND Auto Processor
Catalog NEF10AP
Supports assay-specific sample-processing steps. Confirm whether it is required for the selected assay and whether it is included with the proposed configuration.
FREND Heating Block
Catalog NEF10HB
Provides controlled heating for workflows that require an incubation or pretreatment step, including applicable testosterone procedures.
Assay and QC Materials
Assay-specific items
Cartridges, pretreatment materials, lot-specific code chips and quality-control materials must be selected and used according to the applicable assay instructions.
Explore Jant Immunoassay Products
Explore additional immunoassay analyzers, reagents and related products available from Jant Pharmacal.
Explore Immunoassay Products Contact JantA category link does not establish compatibility with a specific analyzer or assay. Confirm the intended use, regulatory status, specimen requirements and system compatibility before implementation.
Important Product Information
- This page describes the original NanoEntek FREND System model F10, not the FREND 2.0 platform.
- The FREND System should not be described broadly as a point-of-care analyzer. Intended setting and CLIA classification are assay-specific, and certain U.S. assay labeling states that the assay is not for point-of-care settings.
- Specimen type, preparation, measuring range, test time, quality control, calibration information and result interpretation vary by assay.
- Some assays require the FREND Auto Processor, Heating Block, pretreatment materials or other dedicated accessories.
- Follow the current package insert and laboratory procedures for every assay. Website content does not replace product labeling.
- Confirm current analyzer and cartridge availability, regulatory status, included components, installation, training, warranty and service coverage before ordering.
Documentation and Resources
Review the available FREND assay menu, then contact Jant for current analyzer documentation and the current instructions for each assay being considered.
FREND Protein Test Menu Request Current Product DocumentationThe linked test-menu document is dated 2019. CPT codes, coverage and reimbursement policies can change and are not guaranteed. Verify current coding and payer requirements independently.
Frequently Asked Questions
The FREND System model F10 is a compact fluorescence immunoassay analyzer that uses disposable microfluidic cartridges to produce quantitative, assay-specific results.
Jant’s product listing includes PSA Plus, TSH, Free T4, testosterone and vitamin D cartridges. Current availability and regulatory status should be confirmed before ordering.
Do not assume that every FREND assay is authorized for point-of-care use. The intended setting and CLIA classification are assay-specific. U.S. labeling for certain FREND assays, including testosterone and vitamin D, states that they are not for point-of-care settings. Follow the current labeling for the individual assay.
The analyzer readout is designed to be rapid, but total turnaround time varies by assay. Some tests require pretreatment, incubation or heating before the cartridge is inserted. Use the current assay instructions when planning workflow and turnaround time.
No. Accepted specimen types and preparation requirements differ by assay. Do not transfer specimen claims from one FREND cartridge to another; use the current package insert for the selected test.
FREND assay kits use assay- and lot-specific information supplied through the applicable code chip. Calibration verification, quality control and maintenance requirements remain assay- and laboratory-specific. Follow the current analyzer manual, assay instructions and laboratory policy.
These accessories support assay-specific preparation steps and are not necessarily required for every cartridge. The vitamin D and testosterone workflows are examples of assays with additional pretreatment requirements. Confirm the required accessories before ordering.
No. They are different analyzer platforms with different hardware and software specifications. This Jant page and catalog number NEF10 describe the original FREND System model F10.
Identify the assays of interest, expected test volume, specimen types and laboratory setting. Jant can then confirm current analyzer and cartridge availability, required accessories, included components, regulatory status, installation, training, warranty and support.
Ordering Information
To confirm current availability, select the appropriate assays or request a quote, call Jant Pharmacal at 800.676.5565
| Catalog Number | Description | Unit of Measurement |
|---|---|---|
| NEF10 | FREND System by NanoEntek, model F10 | 1 unit |
| NEF10AP | FREND Auto Processor | 1 unit |
| NEF10HB | FREND Heating Block | 1 unit |
| FRPS025 | FREND Cartridge, PSA Plus | 25 tests/kit |
| FRTS025 | FREND Cartridge, TSH | 25 tests/kit |
| FRT4020 | FREND Cartridge, Free T4 | 20 tests/kit |
| FRTE020 | FREND Cartridge, Testosterone | 20 tests/kit |
| FRVD020 | FREND Cartridge, Vitamin D | 20 tests/kit |
Confirm current availability, assay status, required accessories and kit configuration when ordering.